Syringe Pump

Easy to use,
high quality syringe pump

Syringe Pump.png
ce.png

0123

TUV.png

SN-50C6T Syringe Pump

Drug library optional

Support 14 languages

  • ACCUTATE: Calibrating automatically, compatible with all brands of syringes 

  • SMART:  With built-in wireless communication module, provides smart networking and management function (SN-50C66TR) 

  • SECURE:  Dual-CPU monitoring, more secure 

  • POWERFUL:  Support speed mode,drip mode, body weight mode,time mode and Drug Library mode 

SPECIFICATIONS (Single-Channel, Body Weight Mode)

Items

Parameter

Syringes

10, 20, 30, 50 ml of calibrated syringes

Flow rate

0.1-1500 ml/h (specified value 0.1 999.9 ml/h, 0.1 ml/h step)
(specified value 1000 ml/h or above, 1 ml/h step)
0.1- 900 ml/h (0.1 ml/h step)
0.1- 600 ml/h (0.1 ml/h step)
0.1- 400 ml/h (0.1 ml/h step)

50 ml syringe


30 ml syringe
20 ml syringe
10 ml syringe

Purge rate

5-1500 ml/h
5-900 ml/h
5-600 ml/h
5-400 ml/h

50 ml syringe
30 ml syringe
20 ml syringe
10 ml svrinqe

KVO flow rate

0.1-1 ml/h
0.1-5 ml/h

Infusion Mode

Speed mode,Body Weight mode,Time mode,Drug Library mode(Optional)

Accuracy of flow rate

(Nominal value)

Accuracy including syringe: within±2%
Mechanical accuracy: within±1%

Display range of volume delivered

0.1- 9999ml     (0.1~999.9 ml, 0.1 ml step)  (1000 - 9999 ml, 1 ml step)

Setting of delivery limit

0.1- 9999ml     (0.1~999.9 ml, 0.1 ml step)  (1000 - 9999 ml, 1 ml step)

Occlusion detection pressure

'H': 800±200 mmHG (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2

'C': 500±100 mmHG (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2

'L': 300±100 mmHG (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2

Alarms

'Occlusion', 'Nearly empty', 'Finish', 'Syringe dislocated',
'Plunger/Clutch disengaged', 'Battery low', 'Battery exhausted',
'Power cable disconnected', 'Flow rate over limit', 'Volume over limit',

'System error', 'Non-operation time over'

Power

AC110-230±10%, 50/60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Continuous operation time of battery: over 6 hours for one channel

when battery is recharged for 12 hours, at flow rate of 5 ml/h.

Operation conditions

Ambient temperature: 5°C ~ 40 °C,
Relative humidity: 20% to 80%

Storage conditions

Ambient temperature: -20°C ~ 55 °C,
Relative humidity: ≤ 95%

Electric shock protection/class

Class I and internal power supply: Type CF, Continuous operation

Power consumption

Approximately 10 W

Language

English, Russian, Chinese

Weight

225kg (with clamp base)

Dimension

306mm (Width) x135mm (Height) x127mm (Depth)

FUNCTION

  • Adjustable alarm sound

  • Calibrating syringe automatically

  • Identifying syringe size automatically

  • 3-level occlusion alarm limits setting

  • Limits setting

  • Delivered volume inquiry

  • 1000 history records

  • Standby mode

  • Automatically reducing impact dose release after occlusion(Anti-Bolus)

  • Automatic charging when connect to the circuit

  • Adjustable button sound

  • Easy installation of syringe

  • 2CPU control

  • Vehicle powersupply interface

  • Drug library

  • Self-testing when startup

  • LCD screen

  • Nearly empty setting(3 modes)

  • Automatically switch to battery when circuit failure

  • Dynamic pressure monitoring

  • Operation error prompt

  • Fast rate control

  • "Purge" button activate safe protection

  • Flowrate setting button lock

  • Abundant optic and sound alarm

  • AC and internal power indication

  • Standard RS232 interface

  • Clear date when power on

  • Multi-direction clamp for either horizont a vertical fixation

  • Manual and programmable bolus